| System performance |
| Backplane bus switching capacity |
1.5 Tbit/s |
| System L2 packet forwarding rate |
SCUB: 72 Mpps |
| SCUN: 726 Mpps(Active/Standby mode), 1452 Mpps(Load-sharing mode) |
| SCUF: 190 Mpps |
| SCUH: 1428 Mpps(Active/Standby mode), 2856 Mpps(Load-sharing mode) |
| Control board switching capacity |
SCUB: 48 Gbit/s |
| SCUN: 480 Gbit/s(Active/Standby mode), 960Gbit/s(Load-sharing mode) |
| SCUF: 128 Gbit/s |
| SCUH: 960 Gbit/s(Active/Standby mode), 1920Gbit/s(Load-sharing mode) |
| Switching/Forwarding delay |
Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 μs. |
| BER in full load |
BER of port when transmitting data in full load < 10 e-7 |
| System |
Redundant configuration |
| System availability in typical configuration |
>99.999% |
| Mean Time Between Failures (year) |
≈45 |
| Configuration |
| Maintenance port |
Number of 10 Mbit/s/100 Mbit/s maintenance Ethernet ports: 1 |
| Number of serial ports for local/remote maintenance: 1 |
| Monitoring port |
Number of environment monitoring serial ports: 1 |
| Maximum number of GPON ports in a subrack |
96 |
| Maximum number of 10G GPON ports in a subrack |
24 |
| Maximum number of P2P FE ports in a subrack |
288 |
| Maximum number of P2P GE ports in a subrack |
288 |
| Maximum number of upstream ports (GE ports in the GIU slot) in a subrack |
8 |
| Maximum number of upstream ports (10GE ports in the GIU slot) in a subrack |
4 |
| Management ports |
| Outband management Ethernet port (RJ-45) |
SCUB/SCUN/SCUF/SCUH control board: 1 Port Per Board |
| Local serial port (Console) |
SCUB/SCUN/SCUF/SCUH control board: 1 Port Per Board |
| Upstream ports |
| GE electrical port |
GICE: 4 Ports Per Board |
| GICG: 2 Ports Per Board |
| GE optical port |
GICF/GICK: 2 Ports Per Board |
| SCUB/SCUN/SCUH/GICD/GSCA: 4 Ports Per Board |
| ETHB/SPUA/SPUF: 8 Ports Per Board |
| SPUC: 40 Ports Per Board |
| 10GE optical port |
X2CS/SPUA: 2 Ports Per Board |
| SPUC: 4 Ports Per Board |
| SPUF: 8 Ports Per Board |
| E1 port |
TOPA: 16 Ports Per Board |
| STM-1 upstream optical port |
TOPA: 2 Ports Per Board |
| PON upstream optical port |
P2CA: 2 Ports Per Board (One PON port is available and the other is backup.) |
| Service ports |
| GPON port |
GPBD/GPBH: 8 Ports Per Board |
| GPFD: 16 Ports Per Board |
| 10G GPON port |
XGBC: 4 Ports Per Board |
| XGBD: 8 Ports Per Board |
| P2P GE optical port |
OPGD/OPGE: Single-fiber bi-directional: 48 Ports Per Board, Two-fiber bi-directional: 24 Ports Per Board |
| P2P FE optical port |
OPFA: 16 Ports Per Board |
| OPGD/OPGE: Single-fiber bi-directional: 48 Ports Per Board, Two-fiber bi-directional: 24 Ports Per Board |
| Ethernet optical port |
ETHB: 8 Ports Per Board |
| E1 port |
H802EDTB: 16 Ports Per Board |
| Device Specifications |
| Dimensions (W x D x H, excluding mounting brackets) |
442.00 mm x 283.20 mm x 263.90 mm |
| Dimensions (W x D x H, including mounting brackets) |
535.00 mm x 283.20 mm x 263.90 mm, for ETSI cabinet |
| 482.60 mm x 283.20 mm x 263.90 mm, for IEC cabinet |
| Weight (empty chassis) |
7.0kg |
| Working environment temperature |
For an indoor cabinet
Configured with 1 subrack: -25°C to +65°C
Configured with 2 subracks: -25°C to +55°C |
| Working environment humidity |
5% RH to 95% RH |
| Atmosphere pressure |
61 kPa to 106 kPa |
| Altitude |
< 4000 m |