| Switching/Forwarding delay | Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 μs. |
| BER in full load | BER of port when transmitting data in full load < 10 e-7 |
| System performance | |
| System | Redundant configuration |
| System availability in typical configuration | >99.999% |
| Mean Time Between Failures (year) | ≈45 |
| Configuration | |
| Maintenance port | Number of 10 Mbit/s/100 Mbit/s maintenance Ethernet ports: 1 |
| Number of serial ports for local/remote maintenance: 1 | |
| Monitoring port | Number of environment monitoring serial ports: 1 |
| Maximum number of GPON ports in a subrack | ETSI Chassis: 256 |
| Maximum number of 10G GPON ports in a subrack | ETSI Chassis: 128 |
| Maximum number of P2P FE ports in a subrack | ETSI Chassis: 768 |
| Maximum number of P2P GE ports in a subrack | ETSI Chassis: 768 |
| Maximum number of upstream ports (GE ports in the GIU slot) in a subrack | 8 |
| Maximum number of upstream ports (10GE ports in the GIU slot) in a subrack | 4 |
| Maximum number of ADSL2+ ports in a subrack | ETSI Chassis:1024 IEC Chassis:896 |
| Maximum number of VDSL2 ports in a subrack | ETSI Chassis:1024 IEC Chassis:896 |
| Maximum number of EFM SHDSL ports in a subrack | ETSI Chassis:512 IEC Chassis:448 |
| Maximum number of TDM SHDSL ports in a subrack | ETSI Chassis:256 IEC Chassis:224 |
| Maximum number of POTS ports in a subrack | ETSI Chassis:1024 IEC Chassis:896 |
| Maximum number of ISDN BRA ports in a subrack | ETSI Chassis:256 IEC Chassis:224 |
| Maximum number of ISDN PRA ports in a subrack | ETSI Chassis:64 IEC Chassis:56 |
| Management ports | |
| Outband management Ethernet port (RJ-45) | SCUB/SCUN/SCUF/SCUH control board: 1 Port Per Board |
| Local serial port (Console) | SCUB/SCUN/SCUF/SCUH control board: 1 Port Per Board |
| Upstream ports | |
| GE electrical port | GICE: 4 Ports Per Board |
| GICG: 2 Ports Per Board | |
| GE optical port | GICF/GICK: 2 Ports Per Board |
| SCUB/SCUN/SCUH/GICD/GSCA: 4 Ports Per Board | |
| ETHB/SPUA/SPUF: 8 Ports Per Board | |
| SPUC: 40 Ports Per Board | |
| 10GE optical port | X2CS/SPUA: 2 Ports Per Board |
| SPUC: 4 Ports Per Board | |
| SPUF: 8 Ports Per Board | |
| E1 port | TOPA: 16 Ports Per Board |
| STM-1 upstream optical port | TOPA: 2 Ports Per Board |
| PON upstream optical port | P2CA: 2 Ports Per Board |
| Service ports | |
| GPON port | GPBD/GPBH: 8 Ports Per Board |
| GPFD: 16 Ports Per Board | |
| 10G GPON port | XGBC: 4 Ports Per Board |
| P2P GE optical port | OPGD/OPGE: Single-fiber bi-directional: 48 Ports Per Board, Two-fiber bi-directional: 24 Ports Per Board |
| P2P FE optical port | OPFA: 16 Ports Per Board |
| OPGD/OPGE: Single-fiber bi-directional: 48 Ports Per Board, Two-fiber bi-directional: 24 Ports Per Board | |
| Ethernet optical port | ETHB: 8 Ports Per Board |
| E1 port | H802EDTB: 16 Ports Per Board |
| ADSL2+ | ADPD/ADQD/ADKM/ADPE/ADPM |
| VDSL2 | VDRD |
| VDMF/VDNF/VDJM/VCMM | |
| VDPE/VDPM/VDQM/VDPD/VCPE | |
| EFM SHDSL | SHLM |
| SHGM | |
| TDM SHDSL | H802EDTB: 16 Ports Per Board |
| POTS | ASPB : 64 Ports Per Board |
| ADSL2+&POTS | CAME : 48 Ports Per Board |
| VDSL2&POTS | CVME : 48 Ports Per Board |
| CCPE : 64 Ports Per Board | |
| ISDN BRA | DSRD/DSRE :32 Ports Per Board |
| Device Specifications | |
| Dimensions (W x D x H, including mounting brackets) | ETSI Chassis: 530.00 mm x 275.80 mm x 447.20 mm |
| IEC Chassis: 482.60 mm×275.80 mm×441.70 mm | |
| Dimensions (W x D x H, excluding mounting brackets) | ETSI Chassis: 490.00 mm x 275.80 mm x 447.20 mm |
| IEC Chassis: 442.00 mm×275.80 mm×441.70 mm | |
| Maximum weight (including mounting brackets) | ETSI Chassis: 33 KG |
| IEC Chassis: 30.54 KG | |
| Working environment temperature | For an indoor cabinet Configured with 1 subrack: -25°C to +65°C Configured with 2 subracks: -25°C to +55°C |
| Working environment humidity | 5% RH to 95% RH |
| Atmosphere pressure | 61 kPa to 106 kPa |
| Altitude | < 4000 m |